Click for PDF
Technical Data Sheet
Eastman Tritan™ Copolyester MP150


Applications
  • Pharmaceutical packaging
Key Attributes
  • Does not contain Bisphenol-A (BPA)
  • Does not contain plasticizers
  • Excellent clarity
  • Excellent hydrolytic stability
  • Good heat resistance
  • Good melt flow
  • No pre-drying of film prior to thermoforming
  • Outstanding chemical resistance
  • Tremendous toughness
  • Wide thermoforming window

Product Description

Eastman Tritan copolyester MP150 is a high flow grade of Eastman Tritan. Eastman Tritan copolyester MP150 has viscosity reductions of 40-50% relative to Eastman Tritan copolyester MP100. It is intended for use in extrusion coating processes or where high melt flow rate is desirable.

Other outstanding features include good toughness, hydrolytic stability, and heat and chemical resistance. Eastman Tritan copolyester MP150 may be used in food contact applications with restrictions and is compliant with applicable and select sections of USP 35 <661>, ISO10993, and ISO11607.



Typical Properties

PropertyaTest MethodbTypical Value, Unitsc
Film Properties (Cast Film)
Thickness of Film Tested 5 mils
Tear Strength, notched 
     T.D. - Max ForceEMN14 lbf
     T.D. - Work to FractureEMN0.10 J/mm2
Gardner Impact Resistance 
     8-lb. Falling Weight - Mean Fracture EnergyD 54203.5 J
Tensile Strength @ BreakD 88241 lbf
Tensile Stress @ BreakD 8828200 psi
Elongation @ BreakD 882217 %
Tensile ModulusD 882142000 psi
General Properties
Specific GravityD 7921.18
Mold ShrinkageD 9550.005-0.007 mm/mm (0.005-0.007 in./in.)
Mechanical Properties
Tensile Stress @ YieldD 63843 MPa (6200 psi)
Tensile Stress @ BreakD 63852 MPa (7500 psi)
Elongation @ YieldD 6387 %
Elongation @ BreakD 638210 %
Tensile ModulusD 6381575 MPa (2.28 x 105 psi)
Flexural ModulusD 7901575 MPa (2.28 x 105 psi)
Flexural Yield StrengthD 79064 MPa (9300 psi)
Rockwell Hardness, R ScaleD 785111
Izod Impact Strength, Notched 
     @ 23°C (73°F)D 256860 J/m (16.1 ft·lbf/in.)
Impact Strength, Unnotched 
     @ 23°C (73°F)D 4812NB
Optical Properties
Total TransmittanceD 100391 %
HazeD 1003<1 %
Thermal Properties
Deflection Temperature 
     @ 0.455 MPa (66 psi)D 64894 °C (201 °F)
     @ 1.82 MPa (264 psi)D 64881 °C (178 °F)
Glass Transition Temperature (Tg)DSC110 °C (229 °F)
Typical Processing Conditions
Drying Temperature 88 °C (190 °F)
Drying Time 4-6 hrs
Processing Melt Temperature 260-282 °C (500-540 °F)
Mold Temperature 38-66 °C (100-150 °F)

aUnless noted otherwise, all tests are run at 23°C (73°F) and 50% relative humidity.
bUnless noted otherwise, the test method is ASTM.
cUnits are in SI or US customary units.


Eastman Medical Disclaimer
It is the responsibility of the medical device manufacturer ("Manufacturer") to determine the suitability of all component parts and raw materials, including any Eastman product, used in its final product in order to ensure safety and compliance with requirements of the United States Food and Drug Administration (FDA) or other international regulatory agencies. Eastman products have not been designed for nor are they promoted for end uses that would be categorized by either the United States FDA or by the International Standards Organization (ISO) as implant devices. Eastman products are not intended for use in the following applications: (1) in any bodily implant applications for greater than 30 days, based on FDA-Modified ISO-10993, Part 1 "Biological Evaluation of Medical Devices" tests (including any cosmetic, reconstructive or reproductive implant applications); (2) in any cardiac prosthetic device application, regardless of the length of time involved, including, without limitation, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic balloons and control systems, and ventricular bypass assisted devices, or (3) as any critical component in any medical device that supports or sustains human life. For manufacturers of medical devices, biological evaluation of medical devices is performed to determine the potential toxicity resulting from contact of the component materials of the device with the body. Tests are defined in FDA-Modified ISO-10993, Part 1 ''''Biological Evaluation of Medical Devices''''. Limited testing information for certain Eastman products is available upon request. The Manufacturer of the medical device is responsible for the biological evaluation of the finished medical device. The suitability of an Eastman product in a given end-use environment is dependent upon various conditions including, without limitation, chemical compatibility, temperature, part design, sterilization method, residual stresses, and external loads. It is the responsibility of the Manufacturer to evaluate its final product under actual end-use requirements and to adequately advise and warn purchasers and users thereof.

Technical Disclaimer
Although the information and recommendations set forth herein are presented in good faith, Eastman Chemical Company makes no representations or warranties as to the completeness or accuracy thereof. You must make your own determinations of its suitability and completeness for your own use, for the protection of the environment and for the health and safety of your employees and purchasers of your products. Nothing contained herein is to be construed as a recommendation to use any product, process, equipment or formulation in conflict with any patent, and we make no representations or warranties, express or implied, that the use thereof will not infringe any patent. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFER AND NOTHING HEREIN WAIVES ANY OF THE SELLER''''S CONDITION OF SALE. Material Safety Data Sheets providing safety precautions that should be observed when handling and storing our products are available online or by request. You should obtain and review available material safety information before handling our products. If any materials mentioned are not our products, appropriate industrial hygiene and other safety precautions recommended by their manufacturers should be observed.

Comments
Properties reported here are based on limited testing. Eastman makes no representation that the material in any particular shipment will conform exactly to the values given.


Eastman and its marketing affiliates shall not be responsible for the use of this information, or of any product, method, or apparatus mentioned, and you must make your own determination of its suitability and completeness for your own use, for the protection of the environment, and for the health and safety of your employees and purchasers of your products. No warranty is made of the merchantability of fitness of any product, and nothing herein waives any of the Seller's conditions of sale.


8/18/2022 8:26:50 AM