Technical Data Sheet
Eastalite™ Copolyester MP007F


Applications
  • Rigid medical packaging
Key Attributes
  • Can be recycled with other copolyesters for use in nonmedical post-consumer markets
  • Color and functional stability following ethylene oxide (EtO), gamma or e-beam irradiation, or gas plasma sterilization
  • Compliant with applicable sections of ISO 11607 including microbial barrier
  • Complies with select ISO 10993 requirements for biocompatibility of medical devices
  • Decreased thermoforming cycle time and energy use
  • Greater design flexibility including durability, easy printing, deep undercuts, long-life hinges, enhanced product protection
  • Greater tear and flex strength than more brittle and crack susceptible HIPS
  • Light blocking and opacity
  • Light weight Styrene-free alternative
  • Made without other materials of concern, including Latex, Butadiene, BPA and bisphenol S (BPS), ortho-phthalates, PVC, halogens
  • Meets environmentally preferable purchasing guidelines
  • Minimal generation of particulates and angel hair when trimmed or cut
  • Minimal stress whitening
  • Provides good heat seal performance to common lidding materials used with copolyesters
  • Surface modifications are not necessary for COF and blocking force control
  • Sustainable LCA -The global warming potential per tray is 0.33 kg CO2-eq/tray made using MP007F
  • Temperature insulating effect

Product Description
Eastalite™ Foamed Copolyester MP007F with nonporous Eastar™ Copolyester 6763 skins is an opaque, amorphous material with a closed foam structure useful for medical packaging. It is normally white/pearlescent in appearance but may also be colored using Eastman resins and concentrates.

Typical Properties

PropertyaTest MethodbTypical Value, Unitsc
General
Total Thickness of A/B/A Sheet TestedD 3741.01 mm (39.68 mils)
Thickness of Each Eastar™ Copolyester Skin LayerD 3740.06 mm (2.38 mils)
Specific GravityD 7920.78
OpacityEMN88 %
Mechanical Properties
Instrumented Impact, Max LoadD 3763244 N (55 lbf)
Tear Resistance, Graves 
     M.D.D 1004155 N/mm (844 lbf/in.)
     T.D.D 1004163 N/mm (1393 lbf/in.)
Tensile Strength @ Yield 
     M.D.ASTM D 88216.0 MPa (2318 psi)
     T.D.ASTM D 88216.3 MPa (2371 psi)
Tensile Strength @ Break 
     M.D.ASTM D 88218.1 MPa (2619 psi)
     T.D.ASTM D 88218.3 MPa (2659 psi)
Elongation @ Yield 
     M.D.ASTM D 8824.4 %
     T.D.ASTM D 8824.4 %
Elongation @ Break 
     M.D.ASTM D 88253 %
     T.D.ASTM D 88271 %
Youngs Modulus 
     M.D.D 882691 MPa (100160 psi)
     T.D.D 882639 MPa (92687 psi)

aUnless noted otherwise, all tests are run at 23°C (73°F) and 50% relative humidity.
bUnless noted otherwise, the test method is ASTM.
cUnits are in SI or US customary units.


Eastman Medical Disclaimer
It is the responsibility of the medical device manufacturer ("Manufacturer") to determine the suitability of all component parts and raw materials, including any Eastman product, used in its final product in order to ensure safety and compliance with requirements of the United States Food and Drug Administration (FDA) or other international regulatory agencies. Eastman Chemical Company products have not been designed for nor are they promoted for end uses that would be categorized by either the United States FDA or by the International Standards Organization (ISO) as implant devices. Eastman products are not intended for use in the following applications: (1) in any bodily implant applications for greater than 30 days, based on FDA-Modified ISO-10993, Part 1 “Biological Evaluation of Medical Devices” tests (including any cosmetic, reconstructive or reproductive implant applications); (2) in any cardiac prosthetic device application, regardless of the length of time involved, including, without limitation, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic balloons and control systems, and ventricular bypass assisted devices, or (3) as any critical component in any medical device that supports or sustains human life. Eastman Chemical Company products offered for the medical market have met selected FDA-Modified ISO-10993, Part 1 “Biological Evaluation of Medical Devices” tests with human tissue contact time of 30 days or less. The tests include: cytotoxicity, sensitization, irritation or intracutaneous reactivity, systemic toxicity (acute), subchronic toxicity (sub-acute), implantation, hemocompatibility. The Manufacturer is responsible for the biological evaluation of the finished medical device. The suitability of an Eastman Product in a given end-use environment is dependent upon various conditions including, without limitation, chemical compatibility, temperature, part design, sterilization method, residual stresses, and external loads. It is the responsibility of the Manufacturer to evaluate its final product under actual end-use requirements and to adequately advise and warn purchasers and users thereof.


Eastman and its marketing affiliates shall not be responsible for the use of this information, or of any product, method, or apparatus mentioned, and you must make your own determination of its suitability and completeness for your own use, for the protection of the environment, and for the health and safety of your employees and purchasers of your products. No warranty is made of the merchantability of fitness of any product, and nothing herein waives any of the Seller's conditions of sale.